Dip-Switch Delay On Make Timers - TGC Timers


Dip-Switch Delay On Make Timers
TGC Timers

TGC timers with dip-switch adjustment offer precise timing accuracy in a compact 2.5" x 2.5" encapsulated configuration. Three models offer time periods from .10 to 102.3 seconds, 1 to 1023 seconds and 10 to 10230 seconds. The encapsulated relay is capable of switching up to 20 amps (70 amps inrush), 1.5 HP. Advanced circuitry provides this timing module with unsurpassed accuracy and reliability.

Download

Timing Mode

Application of input voltage to the timer starts the time delay. At the end of the delay period, the load is energized. To reset, remove the input voltage to the timer.

FEATURES
  • Precise timing accuracy in three ranges
      0.10 to 102.3 seconds in 0.10 second increments
      1 to 1023 seconds in 1 second increments
      10 to 10230 seconds in 10 second increments
  • Easy to program with 10 position binary dip switch
  • Easy to install with one #8 screw, 1/4" quick connects
  • Timer and contactor in one unit minimizes wiring
  • No leakage in N.O. position
  • No heat sinking required
  • 100% Load isolation
  • Transient and polarity protected
  • No minimum load required
  • Totally encapsulated for protection from harsh environments
  • 0.5% Repeat accuracy
  • 100% Operational testing

BASIC WIRING AND DIMENSIONS
SPECIFICATIONS
Input Voltage:
  • +20%/-10%
  • VDC: 12 or 24
  • VAC: 12,24,120,230, 50/60 Hz
Time Delay:
  • Timing Mode: Delay on Make
  • Type: Digital CMOS
  • Time Range: 0.1 to 102.3 seconds
    1.0 to 1023 seconds
    10 to 10230 seconds
Repeatability: ±0.5%

Setting Accuracy: ±5% or 50 milliseconds, whichever is greater

Reset Time: 50 milliseconds
Relay Life Expectancy:
  • Mechanical: Up to 10 million operations
  • Electrical: 100,000 operations at max. load
Protection:
  • Polarity Protection: All DC units have reverse polarity protection
  • Transient Protection: 18 joules
  • Dielectric Strength: 1800V RMS 60 Hz
Temperature Ranges:
  • Storage: -40°C + 85°C
  • Operating: -25°C to +85°C
Time Adjustment: To set a time period simply add up the switches in the on position for the total delay in seconds
SELECTION PROCEDURE
Mode of Operation Series Input Voltage Time Ranges Time Adjustment Method Relay Output Form Options
Delay On Make TGC    1.  120 VAC   
   2.  230 VAC   
   3.  24 VAC   
   4.  24 VDC   
   7.  12 VDC   



102S3 0.1 to 102.3 seconds
1023 1 to 1023 seconds
10230 10 to 10230 seconds
E Dip Switch
  1. SPDT
  2. SPST (N.O.)
  3. SPST (N.C.)
H 10 amps

J 20 amps 1.5 HP (standard relay output 6 amps)